Brushed Nickel Under Sink Kit
					
					
					
for 
Jupiter Melody and 
					Athena Water Ionizers
					
		
					
					
				
				
					
					
					 
										Uses of Alkaline Water         
					
			
					
					
			
		
					
					
									Benefits of Drinking Alkaline Water        
					Uses of Acid Water 
					
		
					
	
			
		
					
			
					
			
		
		
		
			
			
			What is Microwater?
 Research Articles Experts Comments Testimonials Alkaline Books Alkaline 
			Water Videos 
									
			
					
			
		
					
			
			
					
					
					
								
					
					
			 
					See All Our Alkaline 
			Microwater Ionizers
					
			
			
			
		
					
					
					
						
						This 
						space saving and luxuriously designed and beautiful 
						brass double spouted under sink kit 
						allows your Jupiter 
						Melody JP104 and 
						Athena water ionizers 
						 to be neatly 
						tucked away under your kitchen sink. The previous model only allowed 
						alkaline water, but this one makes available both 
						alkaline and acid water from the same spout. This is a 
						significant improvement. This kit also prevents any 
						water backing up into the ionizer, which was a potential 
						problem with the previous model. If you have heard about 
						the Melody Water Ionizer as many people have, but can't 
						sacrifice the counter space in your kitchen then this is 
						your solution.  
						
						The kit 
						comes with everything necessary for quick and easy installation. All that is needed is a 1-1/2" hole wherever you want the faucet to be located. This faucet has no electric controls so access to the ionizer under the counter is still needed to change pH settings, adjust flow rate or check filter life indicator. 
						Once pH and flow rates are set on your ionizer there is 
						rarely a need to change them. 
						
						As you 
						may already notice several other colors are also 
						available. You can choose from polished chrome, brushed chrome, brushed nickel, brass and white 
						to fit the décor of your kitchen.
						
						
						
						Under The Sink Kit - Installation Instructions
						
						
						
					
					
					This kits 
			enables you to use the Melody as an under the counter installation.
					
					
						
						
						The water 
			source can be either:
1. The cold line of a dishwasher or
2. The cold water pipe.
						
						
						Included are:
1. Vented faucet that ensures a one way flow of water upwards
2. Attachments for dishwasher or cold line.
						
						Important: 
			Please read before you begin Installation
						The waste 
			water line that goes from the bottom of the Melody needs to run 
			downward so that it joins to the dishwasher or waste water line 
			below the bottom of the Melody. Because of this your Melody will 
			need to be raised above floor level
						
						Attaching the 
			Under Sink Kit to cold water pipe:
						
							- 
							
							Decide on 
				position of your ionizer. The closer to the door the better, 
				with easy access to controls. It is good to mount it on the side 
				wall with the screws supplied so that you do not lose storage 
				space for cleaning materials. Also, install as high as possible 
				so to allow for the downhill flow of the acid waste water. 
- 
							
							Attach 
				threaded John Guest valve into the top hole of your ionizer.
							 
- 
							
							Install 
				faucet by using an available hole in the sink or cutting a 1" 
				hole in countertop or sink and fastening it in place. 
				Be sure the location of the faucet allows the outlet spout to 
				extend slightly past the edge of the sink.*
							Our faucet has a 4” overhang 
- 
							
							TURN OFF 
				YOUR COLD WATER SUPPLY VALVE and attach the “T” valve fitting to 
				the cold water supply line.
							 
- 
							
							Attach the 
				Green Tube to the “T” Valve on the Cold Water supply line
							 
- 
							
							Connect 
				the blue hose into the tap water inlet fitting under the Water 
				Ionizer  
- 
							
							Connect 
				the clear hose into the John Guest Valve that you have already 
				installed into the top of the Water Ionizer 
- 
							
							Attach 
				supplied Drain with T to under your sink. 
							
							 
- 
							
							Attach 
				grey (or white) 3/8" tube to acid water outlet. A clamp is not 
				required. If the dishwasher drain is not occupied on the sink 
				drain, open it up and attach the acid water hose, using silicon 
				to seal it. If this is already used, use a hose tee into the 
				dishwasher drain hose to allow it to share the dishwasher 
				drainage point with the dishwasher, or drill a hole in waste 
				pipe and use silicon to fix acid hose in place. In this case, 
				you need to create an S-bend in the acid hose to prevent odor.  
				This can be done using cup hooks on the wall of the cupboard. 
				You will want to cut the length of this hose so it is not too 
				long.  
- 
							
							Turn on 
				the cold water supply and test for leaks.
							 
- 
							
							Plug in 
				the ionizer and turn it on. Select the pH setting you require. 
				Turn on the faucet above sink and test the flow.  
						Attaching
			the 
			Under Sink Kit to Dishwasher 
			cold water hose.
As above except for cold water attachment to dishwasher cold water 
			inlet hose. NOTE: 
			As circumstances are beyond control of JUPITER SCIENCE during 
			installation we accept no responsibility for any consequence of 
			installation. Installation by a third party will be taken as 
			acceptance of this policy. 
						
					
					
				 
					
			
			
				| 
				Jupiter 
				Melody/Athena 
				Under The Sink Kit | 
			
				| 
		
				
		
					
					
				
				 | 
			
				| Melody/Athena Under  
					Sink Kit - Brushed Nickel | $219.95 |  | 
			
				| 
					
					Shipping is 
					FREE 
					with orders over $100.00 |